GDTA Hybrid Optical and Electrical Stranded Loose Tube Cable

GDTA - Single-mode/multimode fibres are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. In the center of cable is a metallic strength member. The tubes and copper wires (of required specifications) are stranded around the central strength member to form a cable core. The core is filled with cable filling compound and armored with laminated aluminum tape. Then, a PE sheath is extruded.

Description
Specification
Package & Shipping
Factory Show
Leave Your Feedback

Cable Section:

GDTA

 

Main Features:

• Accurate process control ensuring good mechanical and temperature performances
• Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment
• Improving manageability of power and reducing coordination and maintenance of power supply
• Reducing procurement costs and saving construction costs
• Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station
• Applicable to duct and aerial installations

 

Technical Characteristics:

Type O.D.(mm) Weight(Kg/km) Tensile strengthLong/short term (N) CrushLong/short term(N/100mm) Structure
GDTA-02-24Xn+2×1.5 11.2 132 600/1500 300/1000 Structure I
GDTA-02-24Xn+2×2.5 12.3 164 600/1500 300/1000 Structure I
GDTA-02-24Xn+2×4.0 14.4 212 600/1500 300/1000 Structure II
GDTA-02-24Xn+2×5.0 14.6 258 600/1500 300/1000 Structure II
GDTA-02-24Xn+2×6.0 15.4 287 600/1500 300/1000 Structure II
GDTA-02-24Xn+2×8.0 16.5 350 600/1500 300/1000 Structure II

Note:

1. Xn refers to fibre type.
2. 2*1.5/2*2.5/2*4.0/2*6.0/2*8.0indicates the number and size of copper wires.
3. Hybrid cables with different numbers and sizes of copper wires can be provided on request.
4. Hybrid cables with different fibre counts can be provided on request.

 

Electrical Performance of Conductor:

Cross section  (mm2) Max. DC resistance ofsingle conductor(20 ℃)(Ω/km) Insulation resistance (20℃)(MΩ.km) Dielectric strength KV, DC 1minstrength KV, DC 1min
Between each conductor and othermetal members connected in cable Betweenconductors Between conductorand metallic armor Between conductorand steel wire
1.5 13.3  No less than 5,000  5  5  3
2.5 7.98
4.0 4.95
5.0 3.88
6.0 3.30
8.0 2.47

Environmental Characteristic:

• Transport/storage temperature: -40℃ to +70℃

 

Delivery Length:

 • Standard length: 2,000m; other lengths are also available. 

 

Write your message here and send it to us

Cable Section:

GDTA

 

Main Features:

• Accurate process control ensuring good mechanical and temperature performances
• Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment
• Improving manageability of power and reducing coordination and maintenance of power supply
• Reducing procurement costs and saving construction costs
• Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station
• Applicable to duct and aerial installations

 

Technical Characteristics:

Type O.D.(mm) Weight(Kg/km) Tensile strengthLong/short term (N) CrushLong/short term(N/100mm) Structure
GDTA-02-24Xn+2×1.5 11.2 132 600/1500 300/1000 Structure I
GDTA-02-24Xn+2×2.5 12.3 164 600/1500 300/1000 Structure I
GDTA-02-24Xn+2×4.0 14.4 212 600/1500 300/1000 Structure II
GDTA-02-24Xn+2×5.0 14.6 258 600/1500 300/1000 Structure II
GDTA-02-24Xn+2×6.0 15.4 287 600/1500 300/1000 Structure II
GDTA-02-24Xn+2×8.0 16.5 350 600/1500 300/1000 Structure II

Note:

1. Xn refers to fibre type.
2. 2*1.5/2*2.5/2*4.0/2*6.0/2*8.0indicates the number and size of copper wires.
3. Hybrid cables with different numbers and sizes of copper wires can be provided on request.
4. Hybrid cables with different fibre counts can be provided on request.

 

Electrical Performance of Conductor:

Cross section  (mm2) Max. DC resistance ofsingle conductor(20 ℃)(Ω/km) Insulation resistance (20℃)(MΩ.km) Dielectric strength KV, DC 1minstrength KV, DC 1min
Between each conductor and othermetal members connected in cable Betweenconductors Between conductorand metallic armor Between conductorand steel wire
1.5 13.3  No less than 5,000  5  5  3
2.5 7.98
4.0 4.95
5.0 3.88
6.0 3.30
8.0 2.47

Environmental Characteristic:

• Transport/storage temperature: -40℃ to +70℃

 

Delivery Length:

 • Standard length: 2,000m; other lengths are also available. 

 