banner

GDTS Hybrid Optical and Electrical Stranded Loose Tube Cable

GDTS - Single-mode/multimode fibres are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. In the center of cable is a metallic strength member. The tubes and copper wires (of required specifications) are stranded around the central strength member to form a cable core. The core is filled with cable filling compound and armored with corrugated steel tape. Then, a PE sheath is extruded.

Description
Specification
Package & Shipping
Factory Show
Leave Your Feedback

Cable Section:

GDTS

 

Main Features:

• Accurate process control ensuring good mechanical and temperature performances
• Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment
• Improving manageability of power and reducing coordination and maintenance of power supply
• Reducing procurement costs and saving construction costs
• Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station
• Applicable to duct and aerial installations

 

Technical Characteristics:

Type O.D.(mm) Weight(Kg/km) Tensile strengthLong/short term (N) CrushLong/short term(N/100mm) Structure
GDTS-02-24Xn+2×1.5 11.6 157 600/1500 300/1000 Structure I
GDTS-02-24Xn+2×2.5 12.5 190 600/1500 300/1000 Structure I
GDTS-02-24Xn+2×4.0 14.6 241 600/1500 300/1000 Structure II
GDTS-02-24Xn+2×5.0 15.0 282 600/1500 300/1000 Structure II
GDTS-02-24Xn+2×6.0 15.7 300 600/1500 300/1000 Structure II
GDTS-02-24Xn+2×8.0 16.9 383 600/1500 300/1000 StructureII

Note:

1. Xn refers to fibre type.
2. 2*1.5/2*2.5/2*4.0/2*6.0/2*8.0 indicates the number and size of copper wires.
3. Hybrid cables with different numbers and sizes of copper wires can be provided on request.
4. Hybrid cables with different fibre counts can be provided on request.

 

Electrical Performance of Conductor:

Cross section(mm2) Max. DC resistance ofsingle conductor(20 ℃)(Ω/km) Insulation resistance (20℃)(MΩ.km) Dielectric strength KV, DC 1minDielectric strength KV, DC 1min
Between each conductor and othermetal members connected in cable Betweenconductors Between conductorand metallic armor Between conductorand steel wire
1.5 13.3  No less than 5,000  5  5  3
2.5 7.98
4.0 4.95
5.0 3.88
6.0 3.30
8.0 2.47

Environmental Characteristic:

• Transport/storage temperature: -40℃ to +70℃

 

Delivery Length:

 • Standard length: 2,000m; other lengths are also available. 

 

Write your message here and send it to us

Cable Section:

GDTS

 

Main Features:

• Accurate process control ensuring good mechanical and temperature performances
• Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment
• Improving manageability of power and reducing coordination and maintenance of power supply
• Reducing procurement costs and saving construction costs
• Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station
• Applicable to duct and aerial installations

 

Technical Characteristics:

Type O.D.(mm) Weight(Kg/km) Tensile strengthLong/short term (N) CrushLong/short term(N/100mm) Structure
GDTS-02-24Xn+2×1.5 11.6 157 600/1500 300/1000 Structure I
GDTS-02-24Xn+2×2.5 12.5 190 600/1500 300/1000 Structure I
GDTS-02-24Xn+2×4.0 14.6 241 600/1500 300/1000 Structure II
GDTS-02-24Xn+2×5.0 15.0 282 600/1500 300/1000 Structure II
GDTS-02-24Xn+2×6.0 15.7 300 600/1500 300/1000 Structure II
GDTS-02-24Xn+2×8.0 16.9 383 600/1500 300/1000 StructureII

Note:

1. Xn refers to fibre type.
2. 2*1.5/2*2.5/2*4.0/2*6.0/2*8.0 indicates the number and size of copper wires.
3. Hybrid cables with different numbers and sizes of copper wires can be provided on request.
4. Hybrid cables with different fibre counts can be provided on request.

 

Electrical Performance of Conductor:

Cross section(mm2) Max. DC resistance ofsingle conductor(20 ℃)(Ω/km) Insulation resistance (20℃)(MΩ.km) Dielectric strength KV, DC 1minDielectric strength KV, DC 1min
Between each conductor and othermetal members connected in cable Betweenconductors Between conductorand metallic armor Between conductorand steel wire
1.5 13.3  No less than 5,000  5  5  3
2.5 7.98
4.0 4.95
5.0 3.88
6.0 3.30
8.0 2.47

Environmental Characteristic:

• Transport/storage temperature: -40℃ to +70℃

 

Delivery Length:

 • Standard length: 2,000m; other lengths are also available. 

 

Optical Cable Factory

Send your message to us:

Write your message here and send it to us