Structure Design

Introductio fibrarum opticorum
Tubus centralis solutus, FRP Fortis membrum Duo, funiculus rip unus; Application for local area Network.
Fibra Optical Technical Parameter Nec. | Items | Unitas | Specification |
G.652D |
1 | ModusField Diameter | 1310nm | μm | 9.2±0.4 |
1550nm | μm | 10.4±0.5 |
2 | Diameter Cladding | μm | 125±0.5 |
3 | Cladding Non-Circularity | % | ≤0.7 |
4 | Core Cladding Concentricitas Error | μm | ≤0.5 |
5 | Coing Diameter | μm | 245±5 |
6 | Coating Non-Circularity | % | ≤6.0 |
7 | Error Cladding-Coating Concentricitas | μm | ≤XII.0 |
8 | Cable Cutoff Necem | nm | λcc≤1260 |
9 | Attenuation (max.) | 1310nm | dB/km | ≤0.36 |
1550nm | dB/km | ≤0.22 |
ASU 80 Fibre Optic Cable Technical Parameter
Items | Specifications |
Fibra comitis | 2~24 fibris |
Span | 120m |
Coloratum Coating Fiber | Dimension | 250mm±15μm |
| Color | Viridis.flavum.White.Blue、Red、Violet、Brown、Pink、Black、Grey、Orange、Aqua |
Cable OD(mm) | 6.6mm±0.2 |
Cable pondus | 42 KGS/KM |
solve Tube | Dimension | 2.0mm |
| Materia | PBT |
| Color | White |
virtus Member | Dimension | 2.0mm |
| Materia | FRP |
Exterior Jacket | Materia | PE |
| Color | Niger |
Mechanica et Environmental Characteres
Items | Unitas | Specifications |
Contentio.Long Term. | N | 1000 |
Contentio.Terminus brevis. | N | 1500 |
Crush.Long Term. | N/100mm | 500 |
Crush.Terminus brevis. | N/100mm | 1000 |
Installation Temperature | ℃ | -0℃ ad + 60℃ |
Operattes Temperature | ℃ | -20℃ ad + 70℃ |
Repono Ttemperatus | ℃ | -20℃ ad + 70℃ |
TEST REQUISITIS
Probatus a variis institutis professionalibus opticis et communicationis productis, GL etiam varias experientias in-domus in proprio Laboratorio et Test Centro gerit. Ea quoque probationem speciali ordinatione administrare cum Ministerio Gubernii Sinensi Qualitatis Supervisionis & Inspectionis Centrum productorum Communicationis Optical (QSICO). GL technologiam habent ut fibra attenuationis detrimentum in signis Industriis custodiant.
Funis est secundum applicabiles normas remulco ac exigentiis emptoris. Sequentia test items perficiuntur secundum congruentem referat. Exercitationes fibra optica probat.
Modus agri diam | IEC 60793-1-45 |
Modus agri Core / induti concentricis | IEC 60793-1-20 |
Diameter Cladding | IEC 60793-1-20 |
Cladding non-circularitas | IEC 60793-1-20 |
Attenuatio coefficientis | IEC 60793-1-40 |
Dispositio chromatica | IEC 60793-1-42 |
Cable abscise adsum | IEC 60793-1-44 |
Tensio Loading Test | |
Test Standard | IEC 60794-1 |
Sample longitudo | Non minus quam L metris |
Load | Maximilianus. installation onus |
Tempus durationis | I hora |
Test eventus | Additional attenuatio:≤0.05dB nullum damnum ad iaccam exteriorem et elementa interiora |
Contundito / Cogo Test | |
Test Standard | IEC 60794-1 |
Load | Contere onus |
Magnitudo plate | 100mm longitudo |
Tempus durationis | I momento |
Test numerus | 1 |
Test eventus | Additional attenuatio:≤0.05dB nullum damnum ad iaccam exteriorem et elementa interiora |
Impulsum Repugnantia Test | |
Test Standard | IEC 60794-1 |
Impact navitas | 6.5J |
Radius | 12.5mm |
Impact puncta | 3 |
Numerus impulsum | 2 |
Test eventus | Additional attenuatio:≤0.05dB |
Repetita tendentes Test | |
Test Standard | IEC 60794-1 |
radii tendentes | 20 X diametri funis |
Cycles | 25 circuitus |
Test eventus | Additional attenuatio:≤0.05dB nullum damnum ad iaccam exteriorem et elementa interiora |
Torsion/Twis Test | |
Test Standard | IEC 60794-1 |
Sample longitudo | 2m |
Angli | ±CLXXX gradus |
circuitus | 10 |
Test eventus | Additional attenuatio:≤0.05dB nullum damnum ad iaccam exteriorem et elementa interiora |
Temperatus revolutio Test | |
Test Standard | IIEC 60794-1 |
Gradus temperatus | +20→-40→+85→+20℃ |
Tempus per se gradus | Transitus ab 0℃ut -40℃:2hours; tempus ad -40℃: VIII horas; Transitus -40℃to +85℃:4hours; spatium ad +85℃: VIII horas; Transitus ab +85℃ad 0℃: 2hours |
Cycles | 5 |
Test eventus | Attenuation variation for reference value (tenuation to be metiri before test at +20"±3℃) ≤0.05 dB/km |
Aquae penetratio Test | |
Test Standard | IEC 60794-1 |
Altitudo columnae aquae | 1m |
Sample longitudo | 1m |
Test tempus | I hora |
Test resul | Nulla aqua lacus ex opposito specimen |
OPERA Manual
Commendatur ut fabricatio et wiring huius funis ASU optici methodum erectionis pendentis adoptet. Haec erectio methodus optimam comprehensionem consequi potest in terminis erectionis efficientiae, erectionis costi, operationis salutis ac tutelae qualitatis funis optici. Methodus operandi: Ne vaginam funis optici laedas, fere methodus tractio trochleae adhibita est. Ut in figura ostenditur, funem ductorem institue et duas machinas in unam partem (finis incipere) et trahens partem (finis terminalis) reel optici, et instituere magnum trochleae (vel ductor trochleae strictae) ad locum convenientem. poli. Coniunge funem tractionem et funem opticum cum lapsus tractu, deinde institue ductorem trocleam omnem 20-30m in linea suspensionis (instructor melior est in trochlea vehi), et quoties trochlea installatur, funis tractio est. transibit per trochlea, et finis trahitur manually vel per tractorem (attendite ad tensionem imperium). ). Funem trahens completur. Ab uno fine, utere funem opticum hamum ad suspendendum funem opticum in linea suspensiva, et repone ductorem trochleae. Distantia inter uncinos et uncinos est 50±3cm. Distantia inter primores uncinos utrinque poli est 25cm circiter a puncto figi pendentis in polo.

Anno 2022, noster ASU-80 funis opticus Anatel certificationem in Brasilia transiit, OCD (ANATEL subsidiaria) certificatorium numerum: Nº 15901-22-15155; libellum interrogationis website: https://sistemas.anatel.gov.br/mosaico/sch/publicView/listarProdutosHomologados.xhtml.