Optica Chara- teristica
Fibra Type | G.652 | G.655 | 50/125^m | 62.5/125^m | |
Attenuation(+20X) | 850 nm | <3.0 dB/km | <3.3 dB/km | ||
1300 nm | <1.0 dB/km | <1.0 dB/km | |||
1310 nm | <0.36 dB/km | <0.40 dB/km | |||
1550 nm | <0.22 dB/km | <0.23 dB/km | |||
Bandwidth | 850 nm | >500 MHz-km | >200 Mhz-km | ||
1300 nm | >500 MHz-km | >500 Mhz-km | |||
Numeralis Apertura | 0.200±0.015 NA | 0.275±0.015 NA | |||
Cable abscise Necem cc | <1260 nm | <1450 nm |
Structura et Specificationes technicae
Cable comitis | Ex vagina Diameter(MM) | Pondus KG/Km) | Minimum licitum Distrahens fortitudo (N) | minimum licita Contere Load(N/100mm) | Minimum Bending Radius (MM) | Repono temperatus . | |||
brevis terminus | diu terminus | brevis terminus | diu terminus | brevis terminus | diu terminus | ||||
24 | 10.5 | 105.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
36 | 10.5 | 105.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
42 | 10.5 | 105.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
48 | 10.5 | 105.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
60 | 10.5 | 105.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
72 | 13.5 | 208.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
96 | 13.5 | 208.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
144 | 15.5 | 295.00 | 1500 | 600 | 1000 | 300 | 20D | 10D | -40+60 |
Notandum:
1, Sola pars Aerei/Duct/Direct Buried/Subterrae/Funiculi cataphracti in mensa recensentur. Rudentes cum aliis determinationibus quaeri possunt.
2, Cables cum fibris simplicibus aut fibris multimodis suppleri possunt.
3,Cable structuram maxime designatam in petitione praesto est.